Home > Products > Molded Case Circuit Breaker > Thermal Magnetic Molded Case Circuit Breaker > Low Voltage 600A Thermal Magnetic Circuit Breakers
Low Voltage 600A Thermal Magnetic Circuit Breakers
  • Low Voltage 600A Thermal Magnetic Circuit BreakersLow Voltage 600A Thermal Magnetic Circuit Breakers
  • Low Voltage 600A Thermal Magnetic Circuit BreakersLow Voltage 600A Thermal Magnetic Circuit Breakers
  • Low Voltage 600A Thermal Magnetic Circuit BreakersLow Voltage 600A Thermal Magnetic Circuit Breakers
  • Low Voltage 600A Thermal Magnetic Circuit BreakersLow Voltage 600A Thermal Magnetic Circuit Breakers
  • Low Voltage 600A Thermal Magnetic Circuit BreakersLow Voltage 600A Thermal Magnetic Circuit Breakers

Low Voltage 600A Thermal Magnetic Circuit Breakers

As trusted suppliers, Saide® ensures that our products meet stringent industry standards, offering peace of mind to our customers. Choose Saide® for high-quality circuit breakers engineered for exceptional performance and protection.

Send Inquiry

Product Description

Low Voltage 600A Thermal Magnetic Circuit Breakers

Saide® stands as a premier supplier of Low Voltage 600A Thermal Magnetic Circuit Breakers in China. Renowned for our unwavering commitment to quality and innovation, we provide top-notch electrical protection solutions. Our circuit breakers are meticulously designed to offer reliable performance and safeguard electrical systems from overcurrents and short circuits.


Technical Data and Performance

Rated Voltage (V) 24~1500 DC
Rated Insulation Voltage (V) 1000
Shell Rack Current (A) 100, 160, 250, 400, 500, 600
Tripping Method Thermal Magnetic
Number of Poles (P) 1, 2, 3, 4
Electrical Life (times) 2000
Breaking Capacity (kA) 20
Rated Impulse Voltage (kV) 8
Standards Compliant IEC/EN60947-2 GB14048.2
Derating When ambient temperature exceeds 40°C, the overload protection characteristics of the product will change little with temperature, and Ir needs to be set to ensure use in a high-temperature environment. When altitude is above 2000m, it is necessary to consider the change of dielectric strength and the factor of air temperature drop, so derating is also required.
Temperature No more than 50%
Pollution Level 3
Ambient Temperature (°C) -25 ~ +70
Altitude (m) 2000
Wiring Series Parallel
Product Accessories Auxiliary contacts (OF, SD, SDE), trip coils (MX, MN), etc.
Installation Method Fixed, plug-in, draw-out
Installation Direction Horizontal or vertical
Contact Structure Double breakpoint
Product Polarity Non-polar
Use Category A


lf the sensitivity is set to 30mA,the stripper is instantaneous clasp.

Note: Fixed installation (1, 2, 3, 4P), plug-in and pull-out (3, 4P)

1.Sensitvity setting

2.Delay setting (for selective leakage protection)

3.Calibration of the seal Sleeve

4.Test button-used to simulate leakage failure,to periodically check leakageprotection function

5.Reset bulton (after leakage fault buckle must be reset)

6.Nameplate

7.Location of secondary contacts


Selection of EL6 modules

Model Polar Number Sensitivity (lAn) Delay Adjustable Delay Settings Maximum Break Time (ms) Rated Voltage
EL6-ME 3, 4 Fixed: 0.3 N/A N/A <40 AC50V/60Hz
EL6-MH 3, 4 Fixed: 0.3 Adjustable: 0.03-0.3-1-3-10 Adjustable: 0-60°-150°-310° <40, <140, <300, <800 AC200-440
SDM6-100 3, 4 Fixed: 0.3 N/A N/A <40 AC200-440
SDM6-160 3, 4 Fixed: 0.3 N/A N/A <40 AC200-440
SDM6-250 3, 4 Fixed: 0.3 N/A N/A <40 AC440-500
SDM6-400 3, 4 N/A N/A N/A N/A AC440-500
SDM6-630 3, 4 N/A N/A N/A N/A AC440-500
EL6-MB 3, 4 Adjustable: 0.3-1-3-10-30 Adjustable: 0-60-150-310 <40, <140, <300, <800 AC200-440


Hot Tags: Low Voltage 600A Thermal Magnetic Circuit Breakers, Manufacturers, Suppliers, China, Factory, Price

Related Category

Send Inquiry

Please feel free to give your inquiry in the form below. We will reply you in 24 hours.
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
Reject Accept